In various types of engineering construction, the application of large-diameter PE pipes is becoming more and more extensive. However, the abnormal sound problem during its operation has brought many troubles to the project. For the abnormal sound of large-diameter PE pipes during operation, the vibration source analysis needs to be carried out first. There are many possible vibration sources, such as unstable fluid flow in the pipeline. When the fluid flow rate is fast or slow, it will have irregular impact on the pipeline wall and cause abnormal vibration. Or the pipeline fixing bracket is loose, which cannot effectively restrain the pipeline, causing unnecessary shaking during operation. There may also be external environmental factors, such as vibration generated by large-scale mechanical operations nearby is transmitted to the pipeline. For these vibration sources, the treatment measures are also different. If due to fluid flow rate problems, the pipeline system design can be optimized, such as setting valves reasonably, adjusting pipe diameter, etc., to stabilize the flow rate. For loose brackets, tighten the brackets in time, check whether the installation of the brackets meets the standards, and replace the brackets if necessary. If affected by external environmental vibration, isolation measures can be taken, such as installing shock absorption devices, setting up protective barriers, etc. In daily maintenance, the monitoring of large-diameter PE pipes should also be strengthened, and the pipeline condition should be checked regularly. Potential problems should be found and dealt with in time to ensure its stable operation and reduce the occurrence of abnormal noises and other faults.